NOTE: The information contained in this Manual is designed to assist you in the safe maintenance of the Nailer.
Some illustrations in this Manual may show details or attachments that di er from those on your own Nailer.
MAINTENANCE AND INSPECTION
Read section titled "SAFETY" (pages 3 – 7).
WARNING
Disconnect air hose and remove all nails
from Nailer when:
1) doing maintenance and inspection; and
2) clearing a jam.
1. Clearing a jam
Remove a jammed nail in the following order:
1 DISCONNECT AIR HOSE.
2 Open the nail guide.
3 Insert a rod into the outlet.
Tap the rod with a hammer.
Hammer
Rod
Outlet
4 Remove the jammed nail with a slotted screw
driver.
Nail
5 Cut the deformed collated wire with nippers.
Correct the deformation.
000Book̲NV75A5̲US̲metabo.indb 21
000Book̲NV75A5̲US̲metabo.indb 21
MAINTENANCE
1
Disconnect
air hose
Slotted Screw Driver
6 In case of frequent jam, contact a metabo HPT
authorized service center.
2. Inspecting the push lever
1 DISCONNECT AIR HOSE.
2 Clean the push lever sliding part.
Lubricate it with metabo HPT pneumatic tool lubricant.
Lubricate
3. Inspecting the feeders
1 DISCONNECT AIR HOSE.
2 Clean the knob sliding part.
Lubricate it with metabo HPT pneumatic tool lubricant.
Nail
Guide
Knob
Push Lever
3 Open the nail guide and remove dust.
Lubricate the sliding groove of the feeder and
shafts.
Nail Guide
Nail Stopper (A)
Nail Stopper (B)
English
1
Disconnect
air hose
1
Disconnect
air hose
Nose
Feeder
Opening
Feeder
Shaft
21