Maintenance And Inspection - Metabo HPT NT 50AE2 Manuel D'instructions Et De Sécurité

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English
2 Pull out the nose cap in the direction of the arrow as
shown in the diagram.
○ Attach to the tip of the push lever in the reverse order
of detaching.
Firing head
Push lever
Nose cap
NOTE: The information contained in this Manual is designed to assist you in the safe maintenance of the Nailer.
Some illustrations in this Manual may show details or attachments that diff er from those on your own Nailer.

MAINTENANCE AND INSPECTION

Read section titled "SAFETY" (pages 4 – 8).
● Disconnect air hose and remove all nails
from Nailer when:
1) doing maintenance and inspection; and
2) clearing a jam.
1. Clearing a jam
Remove a jammed nail in the following order:
1 DISCONNECT AIR HOSE.
2 Remove all nails.
3 Release the lock lever and open guide plate.
4 Remove the jammed nail with a slotted-head
screwdriver.
5 Close guide plate and latch.
6 In case of frequent jam, contact a metabo HPT
authorized service center.
18
1 Disconnect
air hose
MAINTENANCE
WARNING
When not using the nose cap, attach to the storage area
in back of the magazine.
Nose cap
3
Lock lever
3
Guide plate
Guide plate
2. Storing
○ When not in use for an extended period, apply a thin
coat of the lubricant to the steel parts to avoid rust.
○ Do not store the Nailer in a cold weather environment.
Keep the Nailer in a warm area.
○ When not in use, the Nailer should be stored in a
warm and dry place.
Keep out of reach of children.