Metabo HPT NV 75A5 Manuel D'instructions Et De Sécurité page 23

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Maintenance chart
ACTION
Drain air line fi lter daily.
Keep lubricator fi lled.
Clean fi lter element and blow air
through fi lter in direction opposite to
normal fl ow daily.
Clean magazine and feeder
mechanism.
Keep push lever working properly.
Lubricate the Nailer after nailing.
Drain air compressor daily.
Operator troubleshooting
Most minor problems can be resolved quickly and easily using the table below.
If problems persist, contact a metabo HPT authorized service center for assistance.
PROBLEM
Nailer operates, but no nail is driven.
Weak drive.
Slow to cycle.
Drives too deep.
Skipping nails. Intermittent feed.
Nails jam.
Driven nail is bent.
Drives properly during normal
operation, but does not drive fully at
faster nailing speeds.
000Book̲NV75A5̲US̲metabo.indb 23
000Book̲NV75A5̲US̲metabo.indb 23
WHY
Prevent accumulation of moisture
and dirt.
Keep the Nailer lubricated.
Prevent clogging of fi lter with dirt.
Prevent a jam.
Promote operator safety and e cient
Nailer operation.
Extend the Nailer life.
Keep the Nailer operated properly.
CHECK METHOD
Check for a jam.
Check function of feeder per page 21. Clean and lubricate.
Check for proper nails.
Check air pressure.
———
Driver blade worn?
Piston O-ring worn or damaged?
Check air pressure.
Check for proper nails.
Check function of feeder per page 21. Clean and lubricate.
Check position of nail holder in
magazine per page 13.
———
Piston O-ring cut or heavily worn?
Check for proper nails.
Driver blade worn?
Check inside diameter of air hose.
English
HOW
Open manual petcock.
Fill with metabo HPT pneumatic tool
lubricant.
Follow manufacturer's instructions.
Blow clean daily.
Blow clean daily.
Supply 5 – 10 drops of lubricant into
the Nailer.
Open petcock on air compressor
tank.
CORRECTION
Clear a jam.
Use only recommended nails.
Increase air pressure. (Do not exceed
120 psi (8.3 bar 8.5 kgf/cm
).)
2
Use metabo HPT pneumatic tool
lubricant.
Contact metabo HPT for replacement.
Reduce air pressure.
(Adjust 70 – 120 psi)
Use only recommended nails.
Adjust nail holder to proper position.
Use metabo HPT pneumatic tool
lubricant.
Contact metabo HPT for replacement.
Use only recommended nails.
Contact metabo HPT for replacement.
Use larger air hose.