Maintenance And Inspection - Metabo HPT NV 75AN Manuel D'instructions Et De Sécurité

Cloueur
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Push Lever
Nose Cap
Nose cap can be removed from the push lever using a
screwdriver or thin rod.
Push lever
Nose cap
NOTE: The information contained in this Manual is designed to assist you in the safe maintenance of the Nailer.
Some illustrations in this Manual may show details or attachments that di er from those on your own Nailer.

MAINTENANCE AND INSPECTION

Read section titled "SAFETY" (pages 4 – 8).
WARNING
Disconnect air hose and remove all nails
from Nailer when:
1) doing maintenance and inspection; and
2) clearing a jam.
1. Clearing a jam
Remove a jammed nail in the following order:
1 DISCONNECT AIR HOSE.
2 Open the nail guide.
3 Insert a rod into the outlet.
Tap the rod with a hammer.
000Book̲NV75AN̲US.indb 19
000Book̲NV75AN̲US.indb 19
Nose cap can be stored on the magazine as shown below.
Nose
Do not
1
Hole
connect air
hose
Protrusion (Inward)
Screwdriver
MAINTENANCE
Nose cap
Magazine
Hammer
Rod
Outlet
English
1
Disconnect
air hose