Installation and operating manual
(PVI-3.8/4.6-I-OUTD Rev.: 1.5)
8.2
Output values
Description
Rated output power
Grid voltage, maximum
operating range
Grid voltage, rated
Grid frequency,
maximum range
Grid frequency, rated
Rated output current
Max. output current
Output over current
protection
Maximum output fault
current
Inrush Current
Power factor range
(*) Grid voltage, maximum operating range for Australia (AS47773): 200 / 264 Vac
WARNING: In case of more than an inverter are linked to the same
connection grid point, It will not be possible to avoid an unbalance of power
on three the phases, in fact the functioning of each device is independent
from the others. (Each inverter will feed the grid with the maximum power it
is able to supply).
Value
PVI–3.8-I-OUTD(-S)
3800 W
180 / 264 Vac (*)
16.5 A
18.2 A
(16 A for UK Version
G83/1)
20 A
< 25A rms (60ms)
Value
PVI–4.6-I-OUTD(-S)
4600 W
230V
47 / 63 Hz
50Hz
22.5 A
negligible
-0.8 to +0.8
Page 91 of 95
20 A
25 A