Converting Type 1 Pressure Regulator for Use with
LP/ Propane
1. Remove pressure regulator cap with a wrench.
2. Remove plastic insert from pressure regulator cap.
• Plastic insert fits tightly in cap.
3. Reverse plastic insert and carefully push plastic
insert firmly into hole in pressure regulator cap.
• Cap must show "LPG10" or "LP10".
Type 1 Pressure Regulator
4. Place pressure regulator cap on pressure regulator
and tighten.
• Insert should not disturb spring in body of regulator.
Converting Type 2 Pressure Regulator for Use with
LP/Propane
(Figure 9)
1. Remove pressure regulator cap with a wrench.
2. Reverse pressure regulator cap.
• Cap must show "LP".
Type 2 Pressure Regulator
3. Place pressure regulator cap on pressure regulator
and tighten.
Converting Broiler Burner for Use with LP\Propane
1. Locate orifice spud attached adjacent to pressure
regulator and remove for later use.
• Orifice spud used for LP/propane gas is stamped
2. Open oven door and locate broiler burner on oven
ceiling.
• Remove oven door to make conversion easier. See
"Removing Oven Door" section.
3. Remove screw securing front of burner to oven ceiling
and remove broiler.
• Be careful not to damage ignitor while removing
broiler.
A
A—Remove Screw
B—Broiler
C—Orifice
Broiler and Orifice Spud
4. Unscrew natural gas burner spud stamped "52" with
5
/
-inch socket wrench and replace with LP/propane
16
burner spud stamped "58".
• Attach unused burner spud near regulator for future
use.
5. Reinstall broiler.
8
B
C