Gas and Electrical Supply Location
Gas supply must be located in the area shown. Gas
connection must not interfere with the electrical
connection.
D
E
C
Electrical
A—8 inches
B—5 inches
Gas
C—5½ inches
D—5 inches
E—4-inch round hole
Gas and Electrical Supply Location
B
A
Electrical Connection Requirements
!
To avoid the risk of serious electrical shock or
property damage, do not cut or remove the third
(ground) prong from the power plug. A 3-wire
grounded conductor system must be used. Relying
on the flexible connector, hard piping or any other
part of the gas supply line as a ground may cause
fire, electrical shock and/or erratic control operation.
Oven must be electrically grounded in accordance with
local codes or in the absence of local codes, with the
National Electrical Code, ANSI/NFPA No. 70-Latest
Edition.
In Canada, electrical connections are to made in
accordance with CSA C22.1 Canadian Electrical Code.
All electrical connections are to be made in accordance
with CSA standards Z240.6.1 electrical requirements for
mobile homes.
Use a 120 volt, 60 hertz, 3-prong receptacle protected by
a 15 amp circuit breaker or time delay fuse. A qualified
electrician should confirm the outlet is properly grounded
and polarized.
If a 2-prong outlet is encountered, home owner must
replace outlet before using oven. Do not cut off cord, use
plug adapter or extension cord, or remove grounding plug.
Grounded Plug and Outlet
5