Seal Openings; Place Oven In Wall; Converting Pressure Regulator For Use With Natural Gas Or Propane Gas - Amana AOGD2750 Serie Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Seal Openings

Openings in wall behind the oven or on floor under oven must
be sealed before sliding oven into position.

Place Oven in Wall

This procedure should be performed by 2 people.
1. Lean oven to each side and remove shipping base.
2. Move wall oven close to wall opening and plug in oven
cord.
3. Secure wall oven to cabinet with 4 screws.
Place Oven in Wall
Converting Pressure Regulator for Use with
Natural Gas or Propane Gas
This oven arrives from factory adjusted for use with natural
gas. If using LP/propane gas is desired, oven must be
converted. See "Type 1" or "Type 2" regulator.
!
To avoid electric shock that can cause personal
injury or death, disconnect main electrical supply to
oven before servicing.
Remove Control Panel
To convert pressure regulator remove oven control panel.
1. Remove 2 screws and lift off top trim.
2. Tilt control panel out to expose electronic range
control.
3. Remove 4 screws and pull out range control to
expose pressure regulator.
• Broiler burner orifice spuds are wired to manifold
behind pressure regulator.
4. After converting broiler burners and wiring orifice
spuds to manifold. After "Testing for Gas Leaks"
section, reverse procedure to reinstall control panel.
Remove Control Panel