Gas Connection - Amana AOGD2750 Serie Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Converting Type 2 Pressure Regulator for Use with
Natural Gas
1. Remove pressure regulator cap with a wrench.
2. Reverse pressure regulator cap.
• Insert shows "NAT" or is blank.
3. Place pressure regulator cap on pressure regulator
and tighten.
Converting Oven Burner for Use with
Natural Gas
Lower burner orifices and air shutters are located behind
front trim. Remove oven trim to convert oven burners.
1. Remove oven doors .
• See "Removing Oven Door" section.
2. Remove screws (3) from each trim piece.
3. Pull trim away from oven.
• Each orifice box has an air channel. Air channel
must be in place before reinstalling trim.
• Reverse procedure to reinstall trim.
4. Turn (loosen) orifice hood counterclockwise 2 full
turns.
5. Replace cover plate and storage drawer.
Converting Broiler Burner for Use with
Natural Gas
1. Locate orifice spud attached adjacent to pressure
regulator and remove for later use.
• Orifice spud used for natural gas is silver and is
stamped "52".
2. Open oven door and locate broiler burner on oven
ceiling.
• Remove oven door to make conversion easier.
See Removing Oven Door section.
3. Remove screw securing front of burner to oven ceiling
and remove broiler.
• Be careful not to damage ignitor as you remove
broiler.
4. Unscrew LP/propane burner spud stamped "58" with
5
/
inch socket wrench and replace with natural gas
16
burner spud stamped "52".
5. Reinstall broiler and, if necessary, oven door.

Gas Connection

Connect gas supply to regulator using hard pipe or
flexible connector (Check local codes). Pressure
regulator supplied with this appliance has a ½ inch NPT
female connection.
• A manual shutoff, not supplied with oven, must be
installed in an accessible location outside of oven.
• Use joint compound that is resistant to action of
propane gas on all male pipe threads.
• Use supplied pressure regulator only.
• Do not overtighten gas fitting when attaching to
pressure regulator. Overtightening may crack regulator.
• Support pressure regulator with wrench when installing
gas fitting.
!
To avoid property damage or personal injury, only use
a new flexible connector that is AGA/CGA design
certified.
• Do not use an old connector.
• Do not reuse a connector after moving appliance.
10
WARNING

Publicité

Chapitres

Table des Matières
loading

Table des Matières