Technical Data - Hilti VC 20-U Mode D'emploi Original

Masquer les pouces Voir aussi pour VC 20-U:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 37
3.8 Instructions for use
Accessories and how they are used
Accessories
PE VC 20 synthetic dust bag (203854)
PE VC 40 synthetic dust bag (203852)
VC 20 paper dust bag (203858)
VC 40 paper dust bag (203856)
VC 20/40 dry filter (2121386)
VC 20/40 universal filter (2121387)
VC 20/40 performance filter (2121388)
Suction hose, 27 x 3.5 m AS
Suction hose, 36 mm
Suction hose, 36 x 5 m AS
VC 20-UM
VC 20-UME
VC 40-UM
VC 40-UME
▶ A plastic dust bag or paper dust bag must always be used. This is essential.

4 Technical data

4.1 Rated voltage
Note
When powered by a generator or transformer, the generator or transformer's power output must be at
least twice the rated input power shown on the rating plate of the appliance. The operating voltage of
the transformer or generator must always be within +5% and -15% of the rated voltage of the appliance.
Rated voltage
Rated power input
Maximum load on built-
in power outlet for elec-
tric tools (if fitted)
Mains connection (type)
Rated voltage
Rated power input
Maximum load on built-
in power outlet for elec-
tric tools (if fitted)
Mains connection (type)
4.2 Maximum volumetric flow rate and maximum vacuum
Maximum
950 W
volumetric
1100 W
flow rate
1200 W
(air)
24
Printed: 01.10.2015 | Doc-Nr: PUB / 5071294 / 000 / 07
All manuals and user guides at all-guides.com
Type of use
Working with mineral materials, wet and dry
Working with mineral materials, wet and dry
Working with wood
Working with wood
Dry
Universal use, wet and dry
Heavy use, wet and dry
Wet and dry
Mainly wet, not for dust
Wet and dry
100 V
110 V
1200 W
1200 W
1600 W
VCTF
A07 QQ­F
3 x 2.0 mm²
3 / 12 AWG
220 - 240 V
220 - 240 V (CH)
1200 W
1200 W
2400 W
1100 W
H07 RN­F 3G 1.5
H07 RN­F 3G 1.5
mm²
mm²
VC 20­U
VC 40­U
55 ℓ/s
55 ℓ/s
61 ℓ/s
61 ℓ/s
61 ℓ/s
61 ℓ/s
110 V
200 V
1100 W
950 W
H07 BQ­F
VCTF
3G 1.5 mm²
3 x 2.0 mm²
220 - 240 V (GB)
240 V (NZ)
1200 W
1200 W
1800 W
1200 W
H07 RN­F 3G 1.5
H07 RN­F 3G 1.5
mm²
mm²
VC 20-UL
VC 40-UL
•/•
•/•
•/•
•/•
•/•
•/•

Publicité

Table des Matières
loading

Table des Matières