Error codes for Power control package 10001702.cry
Error code
Cause and solution
The file 10001702.cry has an error.
1. Insert the SD card in the machine
again.
2. Exchange the SD card.
SD card is not formatted.
The SD card must be formatted in a
PC as FAT. Or use another SD card.
The software does not match this
control unit.
Use a SD card with software that
matches your control unit.
DSP-PCB is defective
Contact MIGATRONIC Service
Data transmission error
Turn on and off the machine.
Exchange the SD card if the error is
displayed again. Contact your dealer
if necessary.
The file 10001702.cry has an error.
1. Insert the SD card in the machine
again.
2. Exchange the SD card.
DSP-PCB is defective
Contact MIGATRONIC Service
The SD card contains too many files
with 10001702.cry-data
Warranty conditions
Migatronic welding machines are quality-tested continuously throughout the production
process and undergo a thorough, quality-assured final function test as assembled units.
The warranty period is 12 months for new welding machines if no registration is carried out.
Upon registration of new welding machines within 6 weeks from invoicing, the warranty period
is extended to 24 months.
Registration must be made on the online address: www.migatronic.com/warranty. The
certificate of registry is proof of the registration and will be sent by e-mail. The original invoice
and the certificate of registry will document to the buyer that the welding machine falls within
the scope of a 24 months warranty period.
If registration is not made, the standard warranty period is twelve months for new welding
machines, as from the date of invoicing to end user. The original invoice is documentation for
the warranty period.
Migatronic provides warranty according to the warranty conditions in force through remedying
defects in the welding machines that can be proved to be caused by improper materials or
workmanship in the warranty period.
As a main rule, warranty is not provided for welding hoses as they are considered to be wear
parts; defects that occur within 6 weeks after putting into operation and which are caused by
improper materials or workmanship will, however, be considered warranty claims.
All forms of transport in connection with a warranty claim fall outside the scope of Migatronic's
warranty and will take place for buyer's own account and risk.
We refer to Migatronic's warranty conditions at www.migatronic.com/warranty
All manuals and user guides at all-guides.com
The machine requires periodical maintenance and
cleaning in order to avoid malfunction and cancellation
of the guarantee.
WARNING !
Only trained and qualified staff members can carry
out maintenance and cleaning. The machine must
be disconnected from the mains supply (pull out
the mains plug!). Thereafter, wait around
5 minutes before maintenance and repairing, as all
capacitors need to be discharged due to risk of
shock.
Wire cabinet
-
Cooling unit
-
-
Power source
-
-
26
MAINTENANCE
Regularly, clean the wire cabinet with compressed
air and check if the grooves and teeth on the wire
drive rolls are worn out.
Liquid level and frost protection must be checked
and cooling liquid refilled as required.
Drain the cooling liquid out of the cooling module
and welding hoses. Remove dirt and flush with
pure water in the tank and cooling hoses. Fill up
with new cooling liquid. The machine is delivered
with a cooling liquid of type propan-2-ol in the ratio
23% propan-2-ol and 77% demineralized water,
which provides an anti-freeze solution up to –9°C.
(See article number in the spare parts list).
Clean the fan blades and the components in the
cooling pipe with clean, dry, compressed air as
required.
A trained and qualified staff member must carry out
inspection and cleaning at least once a year.