Error codes for Power control package 10001702.cry
Error code
Cause and solution
The file 10001702.cry has an error.
1. Insert the SD card in the machine
again.
2. Exchange the SD card.
SD card is not formatted.
The SD card must be formatted in a
PC as FAT. Or use another SD card.
The software does not match this
control unit.
Use a SD card with software that
matches your control unit.
DSP-PCB is defective
Contact MIGATRONIC Service
Data transmission error
Turn on and off the machine.
Exchange the SD card if the error is
displayed again. Contact your dealer
if necessary.
The file 10001702.cry has an error.
1. Insert the SD card in the machine
again.
2. Exchange the SD card.
DSP-PCB is defective
Contact MIGATRONIC Service
The SD card contains too many files
with 10001702.cry-data
CONDITIONS OF WARRANTY
Migatronic (which is hereinafter referred to as "the Supplier") continuously carries out quality control throughout the manufacturing process as
well as check of the complete units through comprehensive testing.
The Supplier provides warranty in accordance with the following provisions, by correcting errors and defects on units, that demonstrably and
within the warranty period may have been caused by faulty material or workmanship.
The warranty period is 24 months for new welding machines, 12 months for new accessories and 6 months for spare parts. The warranty period
is calculated from the date of invoice to the end user from the Supplier or the Supplier's dealer/distributor. The original invoice is proof of the
warranty period.
The warranty period is 12 months or maximum 1,800 operating hours for the CoWelder solution. The warranty period is calculated from the date
of invoice to the end user from the Supplier or the Supplier's dealer/distributor. The original invoice is proof of the warranty period.
The warranty period is 24 months for new welding machines incorporated in robotic, automated and CoWelder solutions. The warranty period is
calculated from the date of invoice to the end user from the Supplier or the Supplier's dealer/distributor. The original invoice is proof of the
warranty period.
The warranty period can be extended to up to 60 months on selected parts by registration at www.migatronic.com of new welding machines not
later than 30 days after the date of purchase. The following welding machines fall within the scope of the extended warranty: Automig, Automig-
i, MIGx series, Omega series, Sigma series, Sigma Galaxy, Pi series, Pi Plasma, Zeta.
Welding torches and intermediary cables are considered as wearing parts, and only errors and defects found within 12 months upon delivery
and due to faulty material or workmanship, will be considered under warranty.
Warranty repairs neither extend nor renew the warranty period.
Any transport of goods or persons in connection with a warranty claim is not covered under the Supplier's warranty obligation and will therefore
be at the buyer's expense and risk.
You can read the complete Warranty Conditions at www.migatronic.com.
MAINTENANCE
The machine requires periodical maintenance and
cleaning in order to avoid malfunction and cancellation
of the guarantee.
WARNING !
Only trained and qualified staff members can carry
out maintenance and cleaning. The machine must
be disconnected from the mains supply (pull out
the mains plug!). Thereafter, wait around
5 minutes before maintenance and repairing, as all
capacitors need to be discharged due to risk of
shock.
Wire cabinet
-
Regularly, clean the wire cabinet with compressed
air and check if the grooves and teeth on the wire
drive rolls are worn out.
Cooling unit
Check cooling liquid level and frost protection and
-
refill cooling liquid as required.
At least once a year, clean the water tank and the
-
water hoses in the welding hose for dirt and rinse
with clean water. Then add new cooling liquid. The
machine comes with a cooling liquid, which
consists of demineralized water, propylene glycol
and benzotriazole. The cooling liquid provides frost
protection to –12°C. See article number in the
spare parts list. The cooling liquid is not considered
hazardous waste. Waste can be disposed of
through the municipal waste disposal system.
Power source
Clean the fan blades and the components in the
-
cooling pipe with clean, dry, compressed air as
required.
A trained and qualified staff member must carry out
-
inspection and cleaning at least once a year.
26