Select level 2 by turning the right control knob until
is displayed. Press the right control knob to
accept your selection and remove the card.
Level 2 locks the same functions as level 1 and the
following functions:
-
Current/wire speed/material thickness
-
Choke
-
Tack weldng ON/OFF
Select level
by turning the right control knob
until
is displayed. Press the right control knob
to accept your selection and remove the card.
Level
locks the same functions as level 2 and
the following functions:
-
Trim voltage/voltage
-
4-stroke ON/OFF
No matter which level is selected, it will always be
possible to control the machine from a robot interface
and to use the functions:
-
Inching
-
Gas test
-
Change of sequence (using either control
panel or trigger).
Reinsert the Migatronic lock card to unlock the control
panel. The lock symbol
Connection/disconnection of water cooling
(MIG/MAG)
The water cooling function will ensure
protection of the watercooled torch. Water cooling will
be activated automatically when welding starts and
deactivated automatically three minutes after welding
has stopped.
Configuration:
Press the
key for > 5 seconds to get the following
options:
0 = Water cooling disconnected
1 = Water cooling connected (factory setting)
Turn the right control knob until the requested number
is displayed. Press the key at the right-hand side of
the right control knob or the
selection.
®
When a MIG Manager
is connected, it will
automatically control the water cooling function and
disable this configuration.