Events messaging
Events are made up of:
•
TIME and DATE
•
EVENT DESCRIPTION (activation / restoring)
ACTIVATING
RESTORING
ARMING
PARTIALIS.
AREAS ON
DISARMING
TAMPER XX ALRM.
RST, TAMPER XX
ALA.INP.TAMP. XXX
RES.INP.TAMP. XXX
AREA ALARM XX
AREA ALRM RST XX
INP. ALARM XXX
RESTORE INPUT XXX
BATTERY TX XXX
KYP.COM.ERR. XX
IN-MOD. ERR. XX
OUT-MOD. ERR. XX
RADIO.MOD.ERR. XX
RADIO MOD.JAM. XX
TX SUPERVIS. XXX
IN-MOD.T-ALRM XX
OUT-MOD.T-ALM XX
RADIO.MOD.TMP XX
KYP TAMP.ALRM XX
EXIT TEC.MENU
BATTERY FAIL. XX
REST. BATTERY XX
LOCAL CONN.
POWER DOWN XX
REST. POWER XX
•
•
DESCRIPTION 2
CAUSE
There is an arming event when the only operations
are (total or partial) arming When arming all of the
TOTAL
areas managed by the control unit, the second de-
AREAS ON
scription will read TOTAL, whereas for partial arming
the areas on will be shown (example ##--#)
There is a partialisation event when there are oper-
ations of non-total disarming of areas (partial dis-
AREAS ON
arming) The second description will show the on/
off status of the remaining areas (example ##--#)
TOTAL
There is a disarming event when the system is to-
tally off
AREAS DISARMED
Tampering with an opening or a violation at the con-
CONTROL UNIT
trol unit or an auxiliary power supply unit has been
PWR.DESCR.
detected Check the integrity and the tamper
Input xxx has been tampered with (either cut or
short-circuited depending on the balancing) Check
the integrity of the input's electricity line Even if it
INPUT DESCR.
has restored itself "on its own", check the input's
electricity line because there could still be faulty
contacts
When an input goes into alarm mode so do the as-
AREA DESCR.
sociated areas
Input xxx has gone into alarm mode (it has been
INPUT DESCR.
unbalanced)
Radio input xxx's battery is dead Replace it as soon
INPUT DESCR.
as possible
Keypad xx is no longer communicating with the
control unit (red communication LED on keypad not
KEYPAD DESCR.
flashing) Check activation of keypad, bus cabling,
address
The inputs expansion module on bus xx is no longer
communicating with the control unit (red communi-
MODULE DESCR.
cation LED on module not flashing) Check activation
of module, bus cabling, dip switch address
The outputs expansion module on bus xx is no longer
communicating with the control unit (red communi-
MODULE DESCR.
cation LED on module not flashing) Check activation
of module, bus cabling, dip switch address
The radio receiver module on bus xx is no longer
communicating with the control unit (red communi-
MODULE DESCR.
cation LED on module not flashing) Check activation
of module, bus cabling, dip switch address
The radio receiver module on bus xx has detected a
radio transmission that could block any radio trans-
MODULE DESCR.
mitters (JAMMING function activated on control unit)
Radio input xx has transmitted a person-detected
INPUT DESCR.
communication
The tamper device on the inputs expansion module
on bus xx has been tampered with Check module
MODULE DESCR.
tamper
The tamper device on the outputs expansion module
on bus xx has been tampered with Check module
MODULE DESCR.
tamper
The tamper device on the radio receiver module
MODULE DESCR.
on bus xx has been tampered with Check module
tamper
The tamper device on keypad xx has been tampered
KEYPAD DESCR.
with Check keypad tamper
Exiting the technical menu is recorded in the events
memory
CONTROL UNIT
Battery failure in control unit or auxiliary power sup-
ply sources connected to bus
PWR.DESCR.
The communication between the control unit and
local PC (uploading - downloading programming and
events) is recorded in the events memory
CONTROL UNIT
Power down in control unit or auxiliary power supply
sources connected to bus
PWR.DESCR.
EVENT INDEX
EVENT DESCRIPTION (part 2)
Telephone notifications group
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X