Change RS485 Bus speed
RS485 SPEED
115200
Lets you change the communication speed with the various devices
connected on the control unit bus
The possible choices are:
115200 baud (default)
•
38400 baud
•
9600 baud
•
4800 baud
•
2400 baud
•
The devices automatically adjust to the control unit speed
in a maximum time of 30 seconds To allow this, and ensure that
the control unit does not trigger tamper alarms, at switch-on, when
exiting the technical menu, and at the end of programming by PC,
the keypad will display
WAITING FOR SYNC.
Selecting an interface module
For selecting the interface module to use
For the PXWEB/PXGSM, follow the procedure mentioned below
For the PXGPRS, follow the procedure mentioned in the Installation
folder from page 25 onward
DHCP PXLAN/PXWEB activation
PXLAN/PXWEB DHCP
NO
Lets you enable or disable the PXLAN OR PXWEB connection in
DHCP mode If set at NO, you will have to manually set IP ADDRESS,
NETMASK and GATEWAY If, on the other hand, it is set at YES, it will
use the addresses given by the DHCP server
Selection of keypad to duplicate
PXWEB KEYPAD
DUPLICATION 02
Lets you select the address of the keypad that you want to duplicate
(the address of the keypad copied must not go on top of that of a
wired keypad)
Setting IP ADDRESS
192,168,001,100
IPADDR *=MODIF
XXX .168.001.100
IPADDR [192]---
Lets you set the IP address manually (if set to
menu)
PXLAN/PXWEB DHCP
Setting NETMASK
255,255,255,000
NETMASK *=MODIF
XXX.255.255.000
NETMASK [255]---
Lets you set the NETMASK manually (if set to
menu)
PXLAN/PXWEB DHCP
(+)/(-)
(+)/(-)
(+)/(-)
(*)
(0)/(9)
on the
YES
(*)
(0)/(9)
on the
YES
Setting GATEWAY
192,168,001,001
GATEWAY *=MODIF
XXX.168.001.001
GATEWAY [255]---
Lets you set the GATEWAY manually (if set to
menu)
PXLAN/PXWEB DHCP
Setting IP COMPUTER PORT
IP COMPUTER PORT
36821 *=MODIF
IP COMPUTER PORT
36821 -----
Lets you manually set the port for Ethernet connection between the
computer and the PXLAN/PXWEB interface
Setting up the ip port with eti-domo
IP C. TOUCH PORT
36822 *=MODIF
IP C. TOUCH PORT
368222 -----
This is for manually setting up, with ETI-DOMO, the Ethernet con-
nection port
Scenarios
The valid procedure for all programming of scenarios, after access-
ing the Installer/Technical menu, is as follows:
SCENARIOS 03
MODIFY SCENAR. 01 GOING OUT
(▲)/(▼)
(*)
With
you can choose the scenario to programme and press
(▲)/(▼)
(*)
With
you can exit at any time
(#)
Area operation
AREA OPERATION 01
EXACT ON+OFF
The parameter defines the operation that the scenario has to carry
out in the areas, from among those specified in
The scenario does not alter whether the areas are on or off
DISABLED
Example: scenario disabled or scenario for which you
only want to manage the associated output defined in
.
ASSOC. OUTPUT
The selected areas will be forced to switch on and
EXACT ON+ OFF
those deselected to switch off in the exact configuration set
Example: this is the one used most and it is so that
Users may set whether areas are on or off by selecting
scenarios independently from the previous configura-
tion.
GOING OUT
; living areas, bedrooms and perimeter
###
ON;
GOING TO BED
; only living areas and perimeter On
#-#
and bedrooms OFF;
STAYING INDOORS
; only the perimeter is ON.
--#
Only the selected areas switch on, nothing changes
SEL.AREAS ON
with the status of the non-selected areas
Example: used for specifically switching on some are-
as: for example a scenario that only arms the perime-
ter area (perimeter on
--#
(*)
(0)/(9)
on the
YES
(*)
(0)/(9)
(*)
(0)/(9)
(+)/(‒)
ASSOC. AREAS 01
).