Les langues disponibles

'And/or' areas
AND/OR
AREAS
ARM. IF AREAS OR
If several areas are associated to an input the input's armed/dis-
armed status, given by the on/off status of the associated areas,
depends on this parameter:
Input armed if at least one associated area is on
ARM. IF AREAS OR
Example: used when you want to manage partialisa-
tions which share several inputs.
Input armed if all associated areas are on
ARM. IF AREAS AND
Example: if there are two apartments that share the
same garage, two areas are normally associated with
the garage (one for each apartment) and the AND
function is set.
'And' input
AND
INPUT
NO
An input that is programmed as
alarm only if the second input is in a state of alarm This parameter
is normally used to have the function of dual consensus for trigger-
ing an alarm
Example: two sensors are aimed on the same room
and the user wants an alarm to be signalled only when
both sensors go into alarm mode.
Input 1: Type
; And input
IMMEDIATE
Input 2: Type
; And input
IMMEDIATE
Auto-exclusion
AUTOEXCLUS.
[0..10 0=NO] 00
This defines the number of times that the input can go into alarm
mode, beyond which the input is automatically excluded The alarm
counter resets and the input is reincluded if at least one associated
area switches off
Example: a classic example is outdoor sensors.

Automatic re-arming

REARM
INPUT 01
For memory-type inputs it is possible to choose the following meth-
ods of restoration:
the input is re-armed automatically when the input is
AUTOMATIC
closed again
the input is excluded until next re-arming
NEVER
Exclusion of input
NOT
EXCLUDAB.
NO
During arming from a keypad, press key A to exclude open inputs
It is possible to exclude an input, or not, during arming from a key-
pad:
The input can be excluded
NO
the input CANNOT be excluded
YES
Example: the input associated with the house front
door must be non-excludable.
001
(+)/(-)
001
(+)/(-)
with a second input, triggers an
AND
.
INPUT 2
.
INPUT 1
001
(+)/(-)
001
(+)/(-)
001
(+)/(-)
Gong output
GONG
OUTPUT
NO
Allows you to choose whether the input will activate an output de-
clared as the "gong output" or not, and/or the keypads enabled to
ring along with the GONG output Always active irrespective of the
status of associated areas
Example bell on door opening: a classic use of this
function is that of being able to make the keypad ring
after a shop door is opened.
Area 1: indoors.
Area 2: perimeter.
Keypad 1: Associated areas
Front door input: Buzzer output:
.
-#------
Buzzer output keypads:
time: 3 seconds.
Associating output
ASSOC. OUTPUT
NO
Assigns the output to activate if the input is unbalanced If the out-
put controlled is stable in type, when the input is unbalanced the
output is activated, if the input is balanced the output is deactivat-
ed If the output is a pulse one, the output is activated and starts
timing when the input is unbalanced
Depending on the
parameter, managing the output can
CMD ON OUTP.
be linked to the whether the system is on or off
Output command
CMD ON OUTP. 001
ALWAYS
Depending on this parameter, managing the output can be linked to
whether the input is on or off
The output is always commanded by the status of the in-
ALWAYS
put To be more precise: the output is activated if the input is unbal-
anced and reset if the input is balanced
If the input is active, or one or more areas associated with
ARMED
it are armed, the output is commanded by the status of the input To
be more precise: the output is activated if the input is unbalanced
and reset if the input is balanced
If the input is not active, or all the areas associated with
NOT ARMED
it are not armed, the output is commanded by the status of the
input To be more precise: the output is activated if the input is
unbalanced and reset if the input is balanced
Arming
ON
OPERATION
PULSE SWITCH ON
Lets you manage the type of arming/disarming operation on the
areas of the control unit associated with the input
Parameter visible only if the input is an arming one
When the input is unbalanced the control unit arms the areas
When the input is unbalanced the control unit arms the
PULSE ARM
areas
When the input is unbalanced the control unit disarms
PULSE DISARM
the areas
001
(+)/(-)
.
##------
; Associated areas
YES
. Perimeter area buzzer
#-------
001
(+)/(-)
(+)/(-)
001
(+)/(-)

Publicité

Table des Matières
loading

Table des Matières