GONG buzzer
GONG BUZZER 01
YES
Lets you enable/disable inputs with the GONG property
It is possible to enable whether the keypad must sound for the gong
time
Example: shop entrance doorbell.
Masking keypad
MASKING
NO
Lets you activate/deactivate the GONG function for each individual
keypad
Supervision
SUPERVISION
NO
Lets you activate/deactivate the supervision of the selected keypad
Keypad description
KEYPAD
DESCRIPTION 01
Lets you edit the description of the keypad
With the
keys you can move horizontally, with the alphanumer-
(+)/(-)
ic keys you can edit the description letter by letter
Readers
The valid procedure for all programming of readers, after accessing
the Installer/Technical menu, is as follows:
READERS 06
MODIFY 01 READER
(▲)/(▼)
(*)
reader to be programmed and press
options with
The display illustrated always shows the default
(▲)/(▼)
value of the property With
you can exit at any time
(#)
Associated areas
ASSOC.
###
Associated areas are the areas which can be managed and viewed
from the reader These also represent an AND-type filter on the are-
as managed by the code, the scenario or the system
Example: there is a flat above a ground-floor shop.
The owner wants to be able to manage the flat and the
shop with the same key.
Area 1 = HOME
Area 2 = SHOP
Scenario 1 = CLOSE HOME (
Scenario 2 = CLOSE SHOP (
Reader 1 = Situated in the home: (associated areas =
; scenario L1 =
#-
CLOSE HOME
Reader 2 = Situated in the shop: (associated areas =
; scenario L1 =
-#
CLOSE SHOP
Key 1 = Owner (associated areas =
Key 2 = Employee (associated areas =
(+)/(‒)
02
(+)/(-)
02
(+)/(-)
01
(*)/(#)
; with
choose the
01
(▲)/(▼)
; finally browse through the
(*)
AREAS
(+)/(‒)
; areas =
)
SEL. AREAS ON
#-
;areas =
)
SEL. AREAS ON
-#
)
)
)
##
)
-#
Scenarios
SCENARIO L1
GOING OUT
①
②
SCENARIO L2
GOING TO BED
③
SCENARIO L3
STAYING INDOORS
Associate the scenarios with the three reader LEDs
With
choose the scenario to be associated
(+)/(-)
Tamper
TAMPER 01
NO
Lets you enable/disable the reader tamper device
The reader tamper device controls the control unit's com-
munication
Entry buzzer
ENTRY BUZZER 01
YES
Lets you enable/disable the buzzer during entry time
Exit buzzer
EXIT BUZZER 01
YES
Lets you enable/disable the buzzer during exit time
Alarm buzzer
ALARM BUZZER 01
YES
Lets you enable/disable the buzzer during control unit alarm time
Reader description
READER
DESCRIPTION 01
Lets you edit the description of the reader
With the
keys you can move horizontally, with the alphanumer-
(+)/(-)
ic keys you can edit the description letter by letter
01
(+)/(‒)
01
(+)/(‒)
01
(+)/(‒)
(+)/(‒)
(+)/(‒)
(+)/(‒)
(+)/(‒)
01
(*)/(#)