NINFA 32 MCS
"In" - Information Menu
The card can display the following information:
Table. 3
t01
NTC Heating sensor (°C)
t02
NTC DHW sensor (°C)
t03
Not used
t04
NTC External sensor (°C)
t05
NTC Safety sensor (°C)
L06
Present burner power (%)
F07
Present domestic hot water drawing (l_min/10)
P08
Water pressure switch contact
F09
Present ionisation current (uA)
Thefig. 1list of information can be scrolled with the heating knob (detail 1 - ). In case of damaged sensor, the card dis-
plays hyphens.
To return to the Service Menu just turn the selector (detail 3 - fig. 1) to RESET for 1 second and then to
(summer). Card Service Menu exiting occurs by turning the selector (detail 3 - fig. 1) to RESET for 10 seconds and
then to
(winter) or
"Hi" - History Menu
The microprocessor can memorise the last 10 boiler faults.
The History datum item H1 represents the most recent fault that occurred, whereas the History datum item H10 repre-
sents the least recent. The codes of the faults saved are also displayed in the corresponding menu of the Opentherm
remote temperature control.
Thefig. 1list of faults can be scrolled by means of the heating knob (detail 1 - ).
Table. 4
H1
Fault code
H2
Fault code
H3
Fault code
H4
Fault code
H5
Fault code
H6
Fault code
H7
Fault code
H8
Fault code
H9
Fault code
H10
Fault code
To return to the Service Menu just turn the selector (detail 3 - fig. 1) to RESET for 1 second and then to
(summer). Card Service Menu exiting occurs by turning the selector (detail 3 - fig. 1) to RESET for 10 seconds and
then to
(winter) or
"rE" - Reset History
Turn the selector (detail 3 - fig. 1) to RESET for 3 seconds and then to
stored in the History Menu can be deleted: the card will automatically exit the Service Menu, in order to confirm the op-
eration.
To return to the Service Menu just turn the selector (detail 3 - fig. 1) to RESET for 1 second and then to
(summer).
GB
All manuals and user guides at all-guides.com
(summer).
(summer).
cod. 3540G180 - 02/2008 (Rev. 00)
between 05 and 125 °C
between 05 and 125 °C
--
between -30 and 70 °C (Negative values
flash)
between 05 and 125 °C
00%=Min., 100%=Max
00-99 l_min/10
14 = Closed - 00 = Open
00=burner off
(winter) or
(winter) or
(winter) or
(summer) and all the faults
(winter) or
53