NINFA 32 MCS
Compensation curve and curve offset
Turn the selector (detail 3 - fig. 1) to RESET for 5 seconds
and then to
(winter) or (summer); "CU" is displayed.
Operate the DHW knob (detail 2 - fig. 1) to adjust the required curve from 1 to 10 according to the characteristic (fig. 14).
By setting the curve to 0, sliding temperature adjustment is disabled.
fig. 12 - Compensation curve
Turn the selector (detail 3 - fig. 1) to RESET for 1 second and then to (winter) or
(summer) to
exit compensation
curve setting; "CU" is displayed again.
By turning the heating knob (detail 1 - fig. 1) clockwise, "OF" is displayed.
Operate the DHW knob (detail 2 - fig. 1) to adjust the curve offset (fig. 15).
fig. 13 - Parallel curve shift
Turn the selector (detail 3 - fig. 1) to RESET for 5 seconds and then to (winter) or
(summer) to exit
parallel curve
adjustment mode.