◊ Thermal protection
The charger is fitted with a thermostat. If it gets too hot, the charger will stop working. Place the unit in a ventilated
room, wait until it cools down to turn the charger on (wait 10-20 minutes)
◊ Fuse
The fuse will protect the unit in the following instances:
- Polarity reversal or clamps in short-circuit.
- Starting the vehicle whilst the battery is connected to the charger.
- Charging current is in boost mode for too long or too high and above the nominal current in standard charge mode.
In case of a fuse break, disconnect the clamps from the battery, switch the unit off, change the fuse, set the charger to
the minimum charge output available and reconnect everything as instructed above.
Primary fuse
Secondary fuse
Sulfated battery
Batteries which have been deeply discharged may be charged/recovered. Such batteries may be identified if the
ammeter needle does not (stays at 0) or if the charger stops quickly when in automatic mode.
In this event, set the charger to "Manual" (CA 360), set the charger on the fastest charging speed and monitor it
every hour. If the needle still hasn't moved after 5 hours, the battery cannot be recovered.
TROUBLESHOOTING
Symptoms
The ON/OFF button does not
switch on when set to ON.
The machine's anmeter does
not fluctuate .
The charger is properly
connected but it does not
charge the battery
10
CA 150 / 360
CA 150
(No Gys reference for sells)
Cylindrical 5×20mm - T3.15A
Littelfuse reference : 02153.15MXP
Gys reference : 054516
Type : ATOF blade - 25A
Littelfuse reference : 287025.PXPV
Causes
No mains voltage
Power supply problem.
Clamps in short circuit or polarity
reversal.
The battery that you are trying to
charge is faulty.
Voltage error (12 -24V)
Following intensive use, your
device has entered thermal
protection mode.
Blown fuse
Bad clamp connections.
Wrong charge settings
Following intensive use, your
device has entered thermal
protection mode.
(No Gys reference for sells)
Cylindrical 5× 20mm - T5A
Littelfuse reference : 0215005.MXP
Gys reference : 054622
Type: BF1 – M5 - 32V 50A
Littelfuse reference : 153.5631.5502
Remedies
Check that the power cord is plugged to a 230V
50/60Hz socket. Check the power supply
network.
Check your mains power supply.
Check that the fuses have not melted and that
the circuit breaker is not tripped
Check the terminals' voltage with a voltmeter.
If this voltage jumps instantaneously to 2.5V
per element, the battery may be sulfated or
damaged.
Chck that the switch is on the right setting (12
or 24V)
Wait 1/4h so the device can cool down.
Replace the fuse by a new one.
Clean the terminals and the clamps. Check the
state of the cables and clamps.
Check that the selected voltage matches the
battery voltage.
Wait 1/4h so the device can cool down.
EN