14.3.5 Dry-running detection
If the pressure falls below a pre-set minimum
pressure for a pre-set length of time, dry running
of the pump is detected and the pump is switched
off.
• The minimum pressure can be defined in menu 2.46.
Menu
P: 4.3bar H: cm
> automatic RW
<
1 select opera-
tional mode
1.01 mode
> automatic
<
1.02 pump manu.
> OFF
<
1.03 valve manu.
> OFF
<
1.99 back with OK
2 equipment
configuration
2.01 WILO RCE
Vx.xx dd.mm.yyyy
2.02 language
> English
<
2.03 sensor type
> 5.00 m
<
2.04 tank form
> standard
<
2.05 tank height
> 000 cm
<
2.06 h sensor
> 025 cm
<
34
Description
Default display:
P:
Current system pressure on the pressure side (discharge
side)
H: Filling height or V: filling volume of the collector tank
(depending on the tank form selected)
RW: Rainwater from collector tank
DW: Potable water from potable water replenishment reser-
voir
FS: Fault-tolerant software active
FP: Furring protection (prevention of lime deposits) active
FT: Flush time active
Main menu: Select operational mode
Selection of the unit's operating mode
(see section 6.1)
Manual switching-on of the pump in manual mode
(for manual mode, see menu 1.01)
Manual opening of the valve in manual mode
(for manual mode, see menu 1.01)
Return to the main menu
Main menu: Equipment configuration
Displays the software version of the unit and its date of issue Vx.xx dd.mm.yyyy
• Password 01 is required
Choice of menu language
• After-sales service password is required
Selection of the level sensor measurement range/sensor type
• Password 01 is required
Selection of tank shape
(The tank height (menu 2.05) and the overflow (menu 2.07)
must be entered first)
• Password 01 is required
Setting of the tank height (H
max
Height (H) at which the sensor is installed above the tank floor
(absolute value)
• The time delay before a fault signal is triggered
after the pressure falls below the minimum can be
set in menu 2.15.
14.4 Overview of the entire menu structure
The following table lists all menu items available
after entering the required password.
)
Parameters
Factory settings
(Display of infor-
mation only)
automatic
automatic
OFF
manual
potable water
ON
OFF
OFF
ON
OFF
OFF
Confirmation with
"OK" button
(Display of infor-
mation only)
Deutsch
Deutsch
Nederlands
English
Français
2.00 m
> 5.00 m
5.00 m
standard
standard
verti.cylin.
horiz.cylin.
spherical
base x height
000 – H
[cm]
000 cm
max
000 – H
[cm]
025 cm
max
H < tank height
(Display of infor-
(menu 2.05)
mation only)
WILO SE 01/2009
<