2.17 action E4
> closes
<
2.21 max. time p
> 000 min
<
2.24 connect E4
> back pressure
<
2.25 alarm level
> 2.07 + 025 cm <
2.50 choice-stop
> F1 = 4
<
2.53 p off var.
> 4.0 ± x.x bar
<
2.54 p actual
> 2.2 bar
<
2.99 back with OK
3 Pump Nomi-
nal Values
3.01 pump operat
> 0000123,00 h
3.02 tank operat
> 0000103,00 h
3.03 topup water
> 0000020,00 h
<
3.99 back with OK
5 Factory data con-
figuration
5.01 data reset
5.99 back with OK
28
Description
• Password 01 is required
To configure an optional sensor connected to input 4 as a
normally open contact ("closes") or normally closed contact
("opens").
(For assignment of sensor, see menu 2.24)
• Password 01 is required
Setting of the maximum permissible continuous running time
for the pump
• Password 01 is required
Selection of sensor assignment on input 4. Discrimination is
by means of an external resistor.
(For the action of the sensor, see menu 2.17)
Display of the alarm level for high-water level (flooding). The fol-
lowing formula applies: overflow height (menu 2.07) + 25 cm.
• Password 02 is required
Display of switch-off logic adapted as appropriate to the
pump. F1 = 4 means switch-off pressure of 4 bar for the MC
304 pump.
• Password 02 is required
Display of the variable pressure for pump switch-off. The
value is calculated as follows: set pressure for pump switch-
off (menu 2.13) + pressure change increment (menu 2.52)
• Password 02 is required
Display of the actual pressure at the pressure sensor
Return to the main menu
Main menu: Pump Nominal Values
Display of the number of hours that the pump has been in
operation
Display of the number of hours of operation with rainwater
Display of the number of hours of operation with potable
water
Return to the main menu
Main menu: Factory data configuration
Resets the parameters to the factory settings
Return to the main menu
Parameters
Factory settings
opens
closes
closes
000 – 360 min
000 min.
000 = deactivated
back pressure
back pressure
overflow
back pr.+overflow
Menu 2.07+/-
2.07 +25 cm
100 cm
(Display of infor-
mation only)
F1 = 0
F1 = 4
F1 = 4
(Display of infor-
F1 = 5
mation only)
F1 = 9
(Menu 2.13 +/-
4.0+x.x bar
menu 2.52)
(MC 304)
(Display of infor-
mation only)
Currently meas-
x.x bar
ured pressure
(Display of infor-
mation only)
Confirmation with
"OK" button
xxxxxxx.xx h
(Display of infor-
mation only)
xxxxxxx.xx h
(Display of infor-
mation only)
xxxxxxx.xx h
(Display of infor-
mation only)
Confirmation with
"OK" button
Confirmation with
"OK" button and
then confirmation
of the query with
the arrow key
Confirmation with
"OK" button
WILO SE 01/2009