Burkert eCONTROL 8611 Guide De Démarrage Rapide page 29

Régulateur de process et commande proportionnelle
Masquer les pouces Voir aussi pour eCONTROL 8611:

Publicité

Les langues disponibles

Les langues disponibles

Functions,ProcessOperatingLevel
0 2 5 . 5
eCONTROL
8611
025.5
L / M
ENTER
O
u
0..... 9
t
0 3 0 . 0
0 2 5 . 5
0 6 5 . 0
Fig. 12: Displays in the AUTOMATIC operating state
Type 8611
display process actual value
The display of the unit depends on the selection made in the UNIT menu
L/M
(see Operating structure of the configuration level Fig. 16).
For MODE = T – F or T + F the display switches between temperature and flow-rate.
For MODE = RATI the display switches between flow-rate Q1 and Q2
display set-point value
The display depends on the selection made in the MODE menu (see Operating structure of the
0 3 0 . 0
SET
configuration level Fig. 15).
RFAC
SET = Display for process control
RFAC = Display for ratio control
For MODE = T – F or T + F the display switches between flow-rate set-point (SP_Q) and
temperture set-point (SP_T).
For MODE = RATI the display switches between ratio factor (RFAC) and
flow-rate set-point (SPQ1).
display process actual value
display set-point value
030.0
display manipulated variable for valve
Display depends on the actuating element selected in the MODE menu (see Operating structure
0 6 5 . 0
PRZV
of the configuration level Fig. 15).
0 6 5 . 0
mA
PRZV = Display pulse duty factor for solenoid valve
V
mA = Display manipulated variable in mA
V = Display manipulatec variable in V
english
29