Télécharger Imprimer la page

Burkert eCONTROL 8611 Guide De Démarrage Rapide page 14

Régulateur de process et commande proportionnelle
Masquer les pouces Voir aussi pour eCONTROL 8611:

Publicité

Les langues disponibles

Les langues disponibles

wall assembly or rail assembly
Adapter for wall assembly
Tab. 1:
Assembly models
7.1.1.
assembly accessories
Model
accessories
Installation in pipeline Flow-rate fitting, Type
S030
Rail assembly
Adapter for rail assembly
Wall assembly
Adapter for wall assembly
The adapters for the wall and rail assembly are included in the
scope of supply of the assembly model.
Tab. 2:
Assembly accessories
14
Adapter for rail assembly
order no.
See data
sheet S030
655980
427098
english
Type 8611
Assembly
7.2.
attachment to a proportional
valve
Attach the process controller Type 8611 to a proportional valve as
described below.
Loosen the 4 screws at the front of the process controller.
NOTe!
Be careful when opening the process controller so as not to
damage the internal cabling.
• Remove the cover carefully from the housing without jerks.
Remove the cover carefully from the housing.
Place the supplied flat seal over the contact tabs.
Attach the housing of the process controller on the contact tabs
and fasten with the valve screw.
Check the correct position of the profile gasket at the housing of
the process controller.
Place cover on the housing of the process controller and fasten
with 4 screws.
If necessary, the cover can also be mounted in a position
rotated by 90 ° to the left or the right.

Publicité

loading