General Information And Intended Use; Safety - Hauff-Technik MIS 60-ND Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

MIS 60-ND
3

General information and intended use

According to their intended use, our products have been designed exclusively for installation in buildings
made from state-of-the-art construction materials. We do not accept liability for use deviating from or
beyond this unless our express written confirmation has been obtained in advance.
For warranty conditions, please see our current General Terms and Delivery Conditions.
We explicitly draw your attention to the fact that no warranty whatsoever applies for any subse-
quent damage occurring as a result of failure to follow the installation instructions or if our products
are used incorrectly or combined with third-party products.
MIS 60-ND is suitable for reliable sealing of micropipes/fibre optic cables, telecommunications cables
or power cables. Suitable for up to 4 cables with 5 - 7 mm outer diameter, or 3 cables with 10
mm outer diameter, or 1 cable/pipe with 6 - 34 mm outer diameter. Can be used with non-guided
underground rockets for trenchless installations.
4

Safety

This section provides an overview of all the main safety aspects for optimum protection of personnel
and a safe installation process.
If there is a failure to observe the instructions and safety information set out here, this may result in
significant hazards.
When installing the MIS 60-ND is imperative to observe the relevant professional association rules,
the VDE provisions, the relevant national safety and accident prevention regulations and your com-
pany's guidelines (work and procedure instructions).
The fitter must wear the relevant protective clothing.
Only intact components may be installed.
The following points must be rigorously observed when handling expansion resin:
Expansion resin: Tangit M 3000
Component B:
contains isocyanate.
Please observe the latest version of the instructions and safety data sheet issued by the
manufacturer.
Of reduced toxicity.
Contains methylene diphenyl diisocyanate, isomers and homologues.
• Harmful to health when inhaled
• Irritates the eyes, breathing organs and skin
• Sensitisation possible through inhalation
• Keep out of reach of children
• In the event of contact with eyes, rinse thoroughly with water and consult doctor
• In the event of contact with skin, wash off immediately with plenty of water and soap
• Wear protective gloves
• In the event of accident or sickness, consult a doctor (show the label of the resin cartridge if
possible)
• Processing temperature: +5°C bis +30°C; optimum: +15°C to +25°C
Art. Nr.: 5090032017