MIS 60-ND
18
NOTE!
Damage to cables that have already been
laid!
If the wall entry pipe is not cut to length carefully and
appropriately, this can result in damage.
• Cables/micropipes that have already been laid (not
shown in Fig.: 14 to 28) must not be damaged!
• To protect the cables/micropipes during the cut-
ting procedure, we recommend that you insert
a protective pipe (e.g. PE pipe, outer diameter
32 mm) into the building entry from inside the
building and push it through to the wall area.
The protruding part of the wall entry pipe must be cut off
using a saw, so that it is fl ush with the wall (see fi g.: 24).
After the wall entry pipe has been cut to length, fi t the wall
19
collar WAR 60 over the end of the pipe and push it into
the drilled hole as far as it will go (see fi g.: 25).
13 Installing the tubular guide elbow (auxiliary equipment)
The tubular guide elbow can be used only for cables
up to Ø 16 mm.
(Article number of tubular guide elbow MIS 60-RB
including adapter (packing unit contains 10)
2900100810)
34
Art. Nr.: 5090032017
Rev.: 00/2018-07-31
EN
Fig.: 24
Fig.: 25