MIS 60-ND
Insert the resin cartridge into the cartridge gun (see fi g.:
15
20).
Fully inject the resin out of the cartridge into the MIS
using even movements on the cartridge gun.
Legend for fi g.: 20
1
Resin cartridge
2
Cartridge gun
NOTE!
Failure to seal due to incorrect installation!
Improper installation can result in damage.
• During the curing time (5–7 min), do not dis-
connect the entire resin system from the MIS!
• The resin cartridge, however, can be taken out
of the cartridge gun immediately after the resin
has been injected. The cartridge must then be
resealed with the bottom cover of the cartridge,
to prevent any resin components from dripping
out (see fi g.: 21).
After the curing time the resin cartridge and the reusa-
16
ble quick tensioning system must be removed (see fi g.:
22).
Legend for fi g.: 22
1
Empty resin cartridge
2
Quick tensioning device MIS 60-SVS
Cut resin fi ller hose to length with a side cutter (see fi g.: 23).
17
Art. Nr.: 5090032017
Rev.: 00/2018-07-31
EN
1
2
Fig.: 20
Fig.: 21
1
2
Fig.: 22
Fig.: 23
33