Hauff-Technik MIS 60-ND Instructions D'installation page 30

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

MIS 60-ND
6
NOTE!
Failure to seal due to incorrect installation!
Improper installation can result in damage.
• The micropipes/cables to be inserted must be
clean and undamaged at the point where they
pass through the seals; otherwise correct sealing
cannot be guaranteed!
We recommend that you apply a lubricant to the micro-
pipes/cables and to the openings of the seal insert so
that the micropipes/cables can slide through more easily
(see fi g.: 8).
In the case of seal inserts 6-12 mm and 4 x 5-7 mm
7
where there is pebble fi ll next to the outside wall, a
rolling gravel tip can be fi tted. (Included in the packing
unit if 6-12 or 4 x 5-7 seal inserts are used).
The cables/micropipes must fi rst be fed through the
rolling gravel tip and then, together, pushed onto the
wall entry pipe into the fi nal position (see fi g.: 9).
If a rolling gravel tip is not required, then the cables/
8
micropipes are fed directly from inside the building
through the openings of the seal insert (see fi g.: 10).
30
Art. Nr.: 5090032017
Rev.: 00/2018-07-31
EN
Fig.: 8
Fig.: 9
Fig.: 10