Hauff-Technik MIS 60-ND Instructions D'installation page 29

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

MIS 60-ND
Clean the core drill hole, along its entire length, with
2
a drill hole cleaning brush and remove any dust or earth
with an industrial vacuum cleaner.
Determine the wall thickness via the core drill hole (see
3
fi g.: 5).
Legend for fi g.: 5
1
Wall thicknesses X
Mark the wall thickness + 30 mm on the wall entry pipe
4
(see fi g.: 6).
Legend for fi g.: 6
1
Wall thicknesses X + 30 mm
5
NOTE!
Failure to seal due to incorrect installation!
Improper installation can result in damage.
• If only one cable/micropipe will be installed, only
one insertion opening may be penetrated.
Penetrate the membranes of the insertion openings with
a suitable tool (e.g. Phillips screwdriver) (see fi g.: 7).
Art. Nr.: 5090032017
Rev.: 00/2018-07-31
EN
1
Fig.: 5
1
Fig.: 6
Fig.: 7