6.1.3 RUBBER-COATED PADS
Check their conditions. If worn-out or broken, change them.
6.2 PERIODICAL MAINTENANCE
6.2.1 EVERY WEEK
Check safety devices every week, as specified in this manual.
Check hydraulic oil level as follows:
Bring the carriages fully down and check that level is at the mark on the tank.
If necessary, top up with hydraulic oil «ESSO NUTO H46» or equivalent through the plug
(T, Fig. 20).
6.2.2 EVERY MONTH
Check lift screws correct tightening;
Check hydraulic system correct sealing; tighten loose unions, if necessary;
Check the condition of hydraulic hoses; if worn out, change them with new equivalent ones;
Check the condition of pins, rollers, bushes, carriage structure and arms with their extensions,
including the amount and condition of the grease; change any damaged part with original
spare parts.
6.2.3 EVERY 200 OPERATING HOURS OR EVERY 5 YEARS, AT THE LATES
Replace hydraulic system oil, discharging the exhausted oil from tank. Clean oil filter. For
this operation, please refer to the relevant table showing the supplied spare parts.
If these operations are carried out with the utmost care, the user will find the equipment in perfect
working conditions upon lift restart.
6.3 EMERGENCY HYDRAULIC PUMP
An emergency hydraulic pump can be installed upon request. This pump will be used in case of
power cut-off and, on some occasions - as described in par. «5.5 Emergency Lowering» - in case
of any lock at the lowering system.
Please note that the Manufacturer is always at your disposal for any service and spare part needs.