Exemple d'application avec automate de type SLC500
5
Codes retour du paramétrage
*******************************************************************
1747-SDN Scanlist Map
******************************************************************
Discrete Input Map:
15
14
I:3.000
R
R
I:3.001
11
11
I:3.002
11
11
I:3.003
10
10
I:3.004
10
10
I:3.005
08
08
I:3.006
08
08
I:3.007
08
08
I:3.008
08
08
I:3.009
08
08
I:3.010
08
08
I:3.011
00
00
I:3.012
00
00
I:3.013
00
00
I:3.014
00
00
I:3.015
00
00
I:3.016
00
00
I:3.017
04
04
I:3.018
04
04
I:3.019
04
04
I:3.020
04
04
I:3.021
04
04
I:3.022
04
04
Discrete Output Map:
15
14
O:3.000
R
R
O:3.001
11
11
O:3.002
10
10
O:3.003
08
08
O:3.004
08
08
O:3.005
08
08
O:3.006
00
00
O:3.007
00
00
O:3.008
00
00
O:3.009
04
04
O:3.010
04
04
O:3.011
04
04
O:3.012
..
..
30
Les adresses-mémoire suivantes ont été créés à l'aide du logiciel du manager DeviceNet.
13
12
11
10
09 08 07 06 05 04 03 02 01 00
R
R
R
R
R
R
11
11
11
11
11 11 11 11 11 11 11 11 11 11 Données-process de l'app. 11
11
11
11
11
11 11 11 11 11 11 11 11 11 11 Données-process de l'app. 11
10
10
10
10
10 10 10 10 10 10 10 10 10 10 Données-process de l'app. 10
10 10 10 10 10 10 10 10 10 10
10
10
10
10
08
08
08
08
08 08 08 08 08 08 08 08 08 08 EP1 Appareil 8 ES Polled
08
08
08
08
08 08 08 08 08 08 08 08 08 08 EP2 Appareil 8 ES Polled
08
08
08
08
08 08 08 08 08 08 08 08 08 08 EP3 Appareil 8 ES Polled
08
08
08
08
08 08 08 08 08 08 08 08 08 08 EP1 Appareil 8 E/S Bit-Strobe
08
08
08
08
08 08 08 08 08 08 08 08 08 08 EP2 Appareil 8 E/S Bit-Strobe
08
08
08
08
08 08 08 08 08 08 08 08 08 08 EP3 Appareil 8 E/S Bit-Strobe
00
00
00
00
00 00 00 00 00 00 00 00 00 00 EP1 Appareil 0 ES Polled
00
00
00
00
00 00 00 00 00 00 00 00 00 00 EP2 Appareil 0 ES Polled
00
00
00
00
00 00 00 00 00 00 00 00 00 00 EP3 Appareil 0 ES Polled
00
00
00
00
00 00 00 00 00 00 00 00 00 00 EP1 Appareil 0 E/S Bit-Strobe
00
00
00
00
00 00 00 00 00 00 00 00 00 00 EP2 Appareil 0 E/S Bit-Strobe
00
00
00
00
00 00 00 00 00 00 00 00 00 00 EP3 Appareil 0 E/S Bit-Strobe
04
04
04
04
04 04 04 04 04 04 04 04 04 04 EP1 Appareil 4 ES Polled
04
04
04
04
04 04 04 04 04 04 04 04 04 04 EP2 Appareil 4 ES Polled
04
04
04
04
04 04 04 04 04 04 04 04 04 04 EP3 Appareil 4 ES Polled
04
04
04
04
04 04 04 04 04 04 04 04 04 04 EP1 Appareil 4 E/S Bit-Strobe
04
04
04
04
04 04 04 04 04 04 04 04 04 04 EP2 Appareil 4 E/S Bit-Strobe
04
04
04
04
04 04 04 04 04 04 04 04 04 04 EP3 Appareil 4 E/S Bit-Strobe
13
12
11
10
09 08 07 06 05 04 03 02 01 00
R
R
R
R
R
R
11
11
11
11
11 11 11 11 11 11 11 11 11 11 Données-process de l'app. 11
10
10
10
10
10 10 10 10 10 10 10 10 10 10 Données-process de l'app. 10
08
08
08
08
08 08 08 08 08 08 08 08 08 08 SP1 Appareil 8 ES Polled
08
08
08
08
08 08 08 08 08 08 08 08 08 08 SP2 Appareil 8 ES Polled
08
08
08
08
08 08 08 08 08 08 08 08 08 08 SP3 Appareil 8 ES Polled
00
00
00
00
00 00 00 00 00 00 00 00 00 00 SP1 Appareil 0 ES Polled
00
00
00
00
00 00 00 00 00 00 00 00 00 00 SP2 Appareil 0 ES Polled
00
00
00
00
00 00 00 00 00 00 00 00 00 00 SP3 Appareil 0 ES Polled
04
04
04
04
04 04 04 04 04 04 04 04 04 04 SP1 Appareil 4 ES Polled
04
04
04
04
04 04 04 04 04 04 04 04 04 04 SP2 Appareil 4 ES Polled
04
04
04
04
04 04 04 04 04 04 04 04 04 04 SP3 Appareil 4 ES Polled
..
..
..
..
.. .. .. .. .. .. .. .. .. .. Bit-Strobe pour appareil 8
Les données Bit-Strobe sont représentées en gras
Manuel Interface bus de terrain DeviceNet DFD11B pour MOVIDRIVE® MDX61B
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
Mot d'état du scanner
Données-process de l'app. 10
R
Mot de commande du scanner