6.3.6 User Configuration page
From menu entry User Configuration it is possible to
administer all users that have access to the device.
Administrator type users can access the product
configuration. Users such as Operators, Users and
Anonymous have limited access to the management
pages.
Fig. 56
The device can be configured only by users
with administration privileges.
6.3.7 Digital I/O Page
In the Digital I/O tab it is possible to configure the
digital channels available in the device. What follows
is a brief description of the configurable parameters
for each digital input.
• Alarm ID: Field used to select the desired digital
input.
• Type: It indicates the default state of the digital
input.
To check correct operation of the alarms, a dot will
appear on the web page. The dot will be green
in normal conditions and red when an alarm is
detected.
Fig. 57
28
6.3.8 Wiper
Do not use the wiper if the outside
temperature is below 0°C or in case of ice.
The integrated wiper does not interfere with the
viewing range of the installed camera.
6.3.9 Washer Page
From the Washer menu, it is possible to configure the
device wash system functions.
• Enable: Enables the washer functions.
• Wiper-on delay: Time interval that passes
between the moment the water is supplied and
the moment the wiper is enabled.
• Wash cycle duration: Duration of the water
supply by the pump.
• Wiper-off delay: Duration of the brushing cycle
after water supply has been terminated.
Fig. 58