4.6 Washing system connection
For further details on configuration and
use, refer to the relative manual.
4.7 Hardware configuration
It is not necessary to configure the device
communication protocol.
4.7.1 Two-way RS-485 TX/RX line
With this setting it is possible to obtain a bi-
directional, half/duplex, communication on the
RS-485-1 line.
Default value: 38400Bd.
Fig. 3
MNVCMVXCAM_1545_EN
RS-485-1
TX/RX
5 Switching on
The automatic pre-heating (De-Ice) process
could be started whenever the device is
switched on and the air temperature is
below 0°C. This process is used to ensure
that the device works properly even at
low temperatures. The duration ranges
depending on environmental conditions
(from 30 minutes up to 90 minutes).
Complete functionality of the product is guaranteed
up to the following ambient temperature: -40°C.
The product is equipped with a firmware protection
that deactivates the video camera in temperatures of
below -40°C.
The unit is switched on by connecting the power
supply.
To switch off the unit disconnect the power.
5.1 First start-up
Make sure that the unit and other
components of the installation are closed
so that it is impossible to come into contact
with live parts.
Make sure that all parts are fastened down
firmly and safely.
9