8.
Move to Audible tone dwell, and set the dwell time of alarm output from 0 to 30 minutes. The alarm
output will be activated during the preset dwell time when the video loss is detected.
NOTE: The alarm output can be reset during alarm activation only by clicking the Acknowledge or
Acknowledge All button in the Video Signal Failure dialog box.
Setting Up the Alarm
1.
Click the Alarm icon.
2.
Move to Enable, and check the box to enable the selected alarm.
3.
Move to From and To, and set the beginning and ending time (00:00 to 24:00) of alarm activation by
holding down and dragging the pointer.
NOTE: In cases where the From hour is later than the To hour, the alarm will be activated at the From time of
the current date until next day's To time. If you set To: 08:00 and From: 18:00, this means the alarm will be
active over night from 6:00 p.m. until 8:00 a.m. the following day.
4.
16-Channel Digital Video Recorder