Télécharger Imprimer la page

Stihl SR 5600 Notice D'emploi page 20

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 31
English
Checking Flow Rate
Place the unit on the ground.
N
Fill the container with water up to
N
10 liter mark.
Machines without pressure pump
Set the "standard" metering knob to
N
6.
Start the machine.
N
Hold the spray tube horizontally, run
N
the engine at full throttle, spray the
contents of the container down to
the 5 liter mark and note the time
taken.
The time required to spray 5 liters fluid
should be betweeen 90 and
120 seconds.
Machines with pressure pump (special
accessory)
Set the metering knob to position 2.
N
Start the machine.
N
Hold the spray tube horizontally, run
N
the engine at full throttle, spray the
contents of the container down to
the 5 liter mark and note the time
taken.
The time required to spray 5 liters fluid
should be betweeen 80 and
110 seconds.
18
In case of deviations:
Check the container, hose system,
N
metering knob and optional
pressure pump for cantamination
and clean if necessary.
Check blower air intake and clean if
N
necessary.
Check engine setting and correct if
N
necessary.
If there is no improvement, contact your
dealer for assistance.
Filling the Container
Stand the sprayer on a level
N
surface.
Close the stop cock.
N
Fill up with thoroughly mixed spray
N
solution – do not exceed 13 liter
mark (arrow).
1
The gasket (1) in the cap must
N
always be lubricated with grease.
Fit the cap and tighten it down
N
firmly.
SR 5600

Publicité

loading