Pull back torch trigger and hold down
Release the torch trigger
Pull back and hold down the trigger once again
Release the torch trigger
I
1
I
I
S
Fig.16
Functional sequence in pulsed-arc welding operation using TR 50mc (4-step)
Practical hint!
When FRONIUS welding torches with twin-function triggers are
used, the facility for lowering the current from main current to
crater-fill current and back again, without interrupting the welding
sequence, is available in the pulsed-arc operating mode as well.
For details of the functional sequence, see "Description of 4-step
operation / variant 2" (page 9, 10 Fig. 7).
Description of operating mode --> regulation of pulse
current I
using TR 52mc remote-control pedal unit
1
A combination of the REMOTE CONTROL PULSING UNIT and
the REMOTE CONTROL PEDAL UNIT is particularly advantage-
ous with manual TIG welding in cases where it is necessary to alter
the welding pulse current during the welding operation. (Where the
welder is dealing with materials of different strengths, for example).
Connecting the remote control unit:
- Link the connecting socket
socket
on the remote-control pulsing unit electrically with the
remote control cable.
- A remote control cable of the same type may be used for linking
the remote-control pulsing unit (socket
pedal unit (socket
).
- Plug in the pug-in connections the right way round, and screw
the coupling ring on as far as possible.
Functional description:
- When the TR 52mc remote-control pedal unit is connected, the
machine automatically switches over to 2-step operation.
- LED indicator
blinks up on the power source
- Set desired operating mode with function selector switch
- The appropriate LED indicator
operating mode electrode (LED indicator
- The mean welding-current amperage is indicated on display A.
- No "Hold" function
- To initiate the ignition process, gently step on the pedal.
- The level of the start arc current, the pulse current I
crater current can also be controlled from the pedal.
- The base current I
that is set using the dial
2
is a constant percentage of the value of the pulse current I
- When the welder takes his foot right off the pedal, the welding
current is switched off, thus interrupting the welding operation.
- Gas post-flow time elapses.
f
(Hz)
I
2
I
E
on the power source and the
) to the remote control
,
or
lights up -
) is possible
and the final
1
on the TR 50mc
Pedal pressed down ð "Welding ON"
Foot off the pedal ð "Welding OFF"
I
t
Fig.17
Functional sequence in pulsed-arc operation, in conjunction with the
TR52mc remote-control pedal unit (2-step)
.
1
16
I
f
1
(Hz)
I
2