9. TECHNICAl DATA

Radio frequency
Power supply
Operating temperature
Protection rating (J4 io motor)
Protection rating (J4 io plate)
Maximum number of associated control
points and sensors
Maximum end of travel cage capacity
(in turns)
Factory set end of travel cage capacity
(in turns)
Safety level (J4 io motor)
Safety level (J4 io plate)
Torque (Nm)
Motor length (mm)
For the J418, the maximum permissible torque for an end of the motor shaft is 12 Nm.
Thermal time
J4 io motors are protected by a thermal cut-out in case of overheating caused by continuous use for
longer than 6 minutes.
Head rail breakdown
For detailed technical information, refer to the specifications sheets and dedicated interface plans.
WT
Motor tilt
The J4 io motor has been designed to operate horizontally:
NOK
72
868-870 MHz io-homecontrol®, two-way Tri-band
230 V ~ 50 Hz
- 20°C to + 70°C
Category II
6
306
20 min
OK
© 2011 Somfy SAS. All rights reserved. 11/2011
IP 54
IP 67
9
200
120
Class I
10
18
321
341
OK
10°