5.4.2. Modifying the angular travel
For optimum operation of the J4 io actuator, it is
essential to adjust the angular travel.
The angular travel is the total angle necessary for the
blind to change from a slats closed position to a slats
fully open position.
The slats fully open position is reached when the slats
no longer tilt and the blind makes an initial raising
movement.
• Press the down button until the lowered position is
reached.
• When the blind is in the lowered position, press the Up
and Down buttons for 5 seconds: the blind moves
briefly.
• Press the "my" button on the control point: the blind
moves briefly.
• Move the slats from the slats closed position to the slats
fully open position by briefly pressing the Up button on the
control point.
• Press the Up button and "my" buttons on the control
point at the same time, until the blind moves.

Programming the first Somfy io local control point

5.5.
5.5.1. Using a pre-programmed Somfy io local control point
(5.2)
Briefly press the PROG button on this control point:
the blind moves briefly, the control point has been
programmed.
5.5.2. After a power cut
• Press the Up and Down buttons on the new control point
simultaneously until the blind moves.
• Briefly press the PROG button on this control point:
the blind moves briefly; the control point has been
programmed.

Checking the settings

5.6.
Check the settings of the upper and lower end limits using the Somfy io local control point.