Step 4. Anti-Tip Procedures - Monogram ZIC360NHLH Instructions D'installation

Réfrigérateur encastré à congélateur en bas 36 po avec guide de conception
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation Instructions - Standard Installation
STEP 4 ANTI-TIP PROCEDURE (CONT)
• Measure up 81 1/2" (207.01 cm) from the floor. Mark
this point on the wall.
• Using a level, draw a horizontal line on the wall at this
height.
• Locate at least 2 studs on the back wall. Mark these
points on the horizontal line.
• Place the bottom of the wall bracket with tabs on the
horizontal line. Align the center notch on the bracket
with the center line on the wall.
Line on Wall
Center
• The anti-tip wall bracket has a series of holes. Select 2
holes that match with the located studs. Make sure the
holes selected are on the center of the studs. Mark the
wall at these points.
• Mark an additional hole at each end of the bracket.
If one of the studs is closer to the end of the bracket,
mark an additional hole towards the center of the
bracket.
Two Additional
Hole Locations at
Ends of Brackets
• Drill 1/2" (1.27 cm) holes into the wall board at the
locations marked for the toggles to be mounted (not the
stud markings).
• Drill 3/16" (0.47 cm)holes into wooden studs where
marked. If steel stud construction, drill 1/2" holes into
the studs where marked. You will use 2 toggles with
the metal studs.
Install Wall Toggles:
The wall toggles and bolts can be ordered as Service Kit
#WR49X10193. Wall toggles are installed in the drywall
and metal studs for stability. Install the wall toggles as
follows:
31-49142 Rev. 2
Wall Bracket
Center
Line On Wall
Wall Studs
• Drill 1/2" (1.27 cm) holes at the wall markings made in
the holes at the ends of the wall bracket.
• Hold the metal channel flat against the plastic straps
and slide the channel through the hole.
• Gently pull back at the
ends of the plastic straps to
make the channel rest flush
behind the wall.
• Hold the ends of the straps
in one hand and slide the
plastic cap along the straps
until the flange of the cap is
flush with the wall.
• Place your thumb between the
plastic straps and bend up and
down to snap the straps off at
the wall.
Install Screws and Bolts:
• Have someone hold the wall bracket centered in place
with each of the holes aligned with the correct opening
in the bracket and level with the horizontal line.
• Insert the lag screws through the bracket and into the
stud. Tighten with a wrench.
Lag Screw
Anti-Tip Wall Bracket
• Insert the bolts into the toggle by hand until snug.
Bolt
Anti-Tip Wall Bracket
15
Plastic Straps
Metal Channel
Cap
Wood Stud
Tighten with a
Drywall or
wrench.
Steel Stud
Wall Toggle