Design Guide - Standard Installation

THE INSTALLATION SPACE

The finished
cutout width
2-5/16"
must be
35-1/2".
84-1/2" max
24" Cutout Depth
Finished
Opening
3-1/2"
5"
10"
Water And Electrical Locations
Electrical and water supply must be located as shown.
The cutout depth must be 24" (60.96 cm)
The refrigerator will project forward, slightly beyond
adjacent cabinetry, depending on your installation.
Allow minimum 1/8" (0.32 cm) air gap between case
back & wall.
Cutout depth beneath a soffit:
When installed beneath a soffit, the soffit cannot
exceed the 24" (60.96 cm) installation depth shown.
The top case trim overlaps the bottom of the soffit.
Additional Specifications
• A 115 volt 60Hz., 15 or 20 amp power supply is
required. An individual properly grounded branch
circuit or circuit breaker is recommended. Install
a properly grounded 3-prong electrical receptacle
recessed into the back wall. Electrical must be
located on rear wall as shown.
• Water line can enter the opening through the floor
or back wall. Route SmartConnect
copper tubing between the cold water line and the
water connection location. The tubing should be
long enough to extend to the front of the refrigerator.
Installation of an easily accessible shut-off valve in
the water line is required.
31-1000451 Rev. 0
35-1/2"
Finished Width
Wall View
6"
Electrical
10"
Area
75" From
Floor to Bottom
Water Supply
of Electrical Area
3-1/2"
5"
10"
3-1/2"
kit or 1/4" O.D.

DIMENSIONS AND CLEARANCES

35"
25-3/8"
Case Width
Case Depth
*83 1/2"
at
Rear
36" Frame to
Frame Width
Depth Including
3/4" Panel - Handles: 25-15/16"
Product Clearances
These refrigerators are equipped with a 3-position
door stop. The factory set 115° door swing can be
adjusted to 90° if clearance to adjacent cabinets or
walls is restricted.
9 1/4"
Min. to
Wall
115°
115°
12-5/16"
Min. to
Wall
130°
130°
Allow 12-5/16" (31.27 cm) minimum clearance for a
full 130° door swing.
For a 90° door swing, allow 4 9/16" (11.59 cm) min.
clearance to adjacent wall from cutout. If the 90°
door stop position is used, pan access is maintained,
but pan removal is restricted.
See illustrations pages 11 and 12 to determine
door swing
interaction with adjacent cabinets or
countertops.
7
* Shipping height. The
refrigerator can be
adjusted to fit into a
cutout that is 83-1/2
(212 cm) min. to 84-1/2
(214.63 cm) max.
*84" From
height. Note that the top
Floor to
Top Frame
case trim at the front is
"
1/2
(1.27 cm) higher
and will overlap upper
cabinetry or soffit. Use
leveling legs and wheels
for a maximum 1
cm) height adjustment.
4 9/16" Min.
Distance to Adjacent
9 1/4"
Wall from Cutout
Min. to
Wall
90°
90°
12-5/16"
Min. to
Wall
"
"
"
(2.54
23-5/8"
Behind
Frame
18-1/2"