The Installation Space - Monogram ZISS480NNSS Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Design Guide - Standard Installation

THE INSTALLATION SPACE

*Finished Width
6-3/4"
Electrical
84 ±1/2"
Area
Finished
Opening
24"
5"
Water Supply
3-1/2"
*The finished cutout width must be:
35-1/2" (90.17 cm) for 36" models
41-1/2" (105.41 cm) for 42" models
47-1/2" (120.65 cm) for 48" models
Water And Electrical Locations
The opening must be prepared with the electrical and the
cold water supply located as
31-1000450 Rev. 1
36" Models 12"
42" Models 18"
48" Models 20"
6-3/4"
75" From Floor
to Bottom
of Electrical
Area
5"
3-1/2"
shown.
The Cutout Depth Must Be 24" (60.96 cm)
The refrigerator will project forward, slightly beyond
adjacent cabinetry for standard installation.
Additional Specifications
• A 115 volt 60Hz., 15 or 20 amp power supply is
required. An individual properly grounded branch circuit
or circuit breaker is recommended. Install a properly
grounded 3-prong electrical receptacle recessed into
the back wall. Electrical must be located on the rear
wall as shown.
• Water line can enter the opening through the floor
or back wall. Route SmartConnect™ kit or 1/4" O.D.
copper tubing between the cold water line and the
water connection location. The tubing should be
long enough to extend to the front of the refrigerator.
Installation of an easily accessible shut-off valve in the
water line is required.
7

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ziss360dnssZiss420nnssZiss480dnssZis420nniiZisb360dnii

Table des Matières