The Installation Space; Grounding The Refrigerator - Monogram ZIK30GNNII Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

THE INSTALLATION SPACE

Water and Electrical Locations
Electrical and water supply should be located in shaded area only as
shown.
WARNING
Connect to potable water supply only.
PREPARING INSTALL WATER LINE
• A cold water supply is required for automatic icemaker operation. The
water pressure must be between 40 and 120 p.s.i. (275-827 kPa).
house cold water line and the water connection location.
• Tubing should be long enough to extend to the front of the encloasure.
• Water line can enter an opening through the floor or back wall.
• Install a shut-off valve between the icemaker water valve and cold water
supply in the home.
NOTE:
• It is recommended that the water shut-off valve be placed in a location
that is easily accessible. We do not advise placing it behind the unit
because of access difficulties. If it is necessary to install the valve behind
the unit, it must be located in the shaded area.
• Saddle type shut-off valves are included in many water supply kits, but
are not recommended for this application.
• The only GEA-approved plastic tubing is supplied in the SmartConnect
other plastic water supply line because the line is under pressure at all times. Other types of plastic may crack or
rupture with age and cause water damage to your home. SmartConnect
the following lengths:
6' (1.8 m) WX08X10006, 15' (4.6 m) WX08X10015 & 25' (7.6 m) WX08X10025
• Commonwealth of Massachusetts Plumbing Codes 248CMR shall be adhered to. Saddle valves are illegal and use
is not permitted in Massachusetts. Consult with your licensed plumber.
Electrical Specifications
• A 115-volt, 60-Hz., 15- or 20-amp power supply is required. An individual properly grounded branch circuit or circuit
breaker is recommended.
• Install a properly grounded 3-prong electrical receptacle recessed into the back wall. Electrical must be located on
rear wall as shown.
NOTE: GFI (ground fault interrupter) is not recommended.

GROUNDING THE REFRIGERATOR

WARNING
Electrical Shock
Hazard.
Failure to follow these instructions can
result in death, fire, or electrical shock.
The power cord of this appliance is equipped with a
3-prong (grounding) plug which mates with a standard
three-prong (grounding) wall receptacle to minimize the
possibility of electric shock hazard from this appliance.
Have the wall outlet and circuit checked by a qualified
electrician to make sure the outlet is properly grounded.
Design Guide
plastic tubing between the
Where a standard 2-prong wall outlet is encountered, it
is your personal responsibility and obligation to have it
replaced with a properly grounded 3-prong wall outlet.
DO NOT, UNDER ANY
CIRCUMSTANCES, CUT
OR REMOVE THE THIRD
(GROUND) PRONG FROM
THE POWER CORD.
DO NOT USE AN ADAPTER PLUG TO CONNECT THE
REFRIGERATOR TO A 2-PRONG OUTLET.
DO NOT USE AN EXTENSION CORD WITH THIS
APPLIANCE.
6
Anti-Tip location. Do
not obstruct this area.
80"
77"
6"
Water and Electrical
Tube
Outlet
Refrigerator Tubing kits. Do not use any
Refrigerator Tubing Kits are available in
Front view
Install Space
31-1000169 Rev. 1

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Zic30gnnii

Table des Matières