Unplug the connector of the ventilator by pressing the grip
By disconnecting, be careful not to tear the wires!
•
Unscrew the six screws of fixed scroll
•
Carefully remove the fixed scroll. Use gentle lateral force, if required
•
Place the fixed scroll assembly on a flat surface
FO 0015 A
•
Remove the used tip seal, using a pointed tool, for instance the
point of the cutter, at the outer beginning of the scroll.
Repeat this operation for both fixed and moving scrolls.
•
Make sure there is no debris visible on the inside of the scroll, inclu-
ded inside the tip seal groove.
Wipe all spirals with a soft, lint-free cloth, impregnated with alcohol,
including the tip seal grooves.
New tip seal
•
With a cutter, cut two small notches (0,3 mm deep each) which will
allow the seal to settle in the groove at the internal start of the scroll
(holding claws)
•
Set and adjust the seal in the groove, starting from the center. The
aim of this step is to mark the location of the two holding claws.
Holding claws