Electrical Service; Voltage; Fuse/Circuit Breaker; Electrical Rating - Manitowoc QM45 Instructions D'installation

Masquer les pouces Voir aussi pour QM45:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation Instructions

Electrical Service

!
All wiring must conform to local, state and national
codes.
Voltage Phase
230/50/1
230/60/1
115/60/1

VOLTAGE

The maximum allowable voltage variation is ± 10% of
the rated voltage on the ice machine model/serial
number plate at start-up (when the electrical load is
highest).
!
The ice machine must be grounded in accordance
with national and local electrical codes.
!
Never use an extension cord. If an outlet is not
within reach of the ice machine's power cord, have
a proper amperage outlet wired closer to the ice
machine.

FUSE/CIRCUIT BREAKER

A separate fuse/circuit breaker must be provided for
each ice machine.
NOTE: A disconnect means must be provided for field
wiring.

ELECTRICAL RATING

The electrical rating is used to help select the wire size
of the electrical supply. The wire size (or gauge) also
depends on location, materials used, length of run, etc.,
so it must be determined by a qualified electrician.
6
Warning
Total Amps
2.6
3.1
5.2
Warning
Warning

Water Service/Drains

WATER SUPPLY

Local water conditions may require treatment of the
water to inhibit scale formation, filter sediment, remove
chlorine, and improve taste and clarity.
Important
If you are installing a Manitowoc Tri-Liminator
water filter system, refer to the Installation
Instructions supplied with the filter system for ice
making water inlet connections.
Follow these guidelines to install water inlet lines:
Connect to potable water supply only.
Do not connect the ice machine to a hot water
supply. Be sure all hot water restrictors installed for
other equipment are working. (Check valves on sink
faucets, dishwashers, etc.)
If water pressure exceeds the maximum
recommended pressure, obtain a water pressure
regulator from your Manitowoc distributor.
Install a water shut-off valve for both the ice making
and condenser water lines (if applicable).
Insulate water lines to prevent condensation.
Important
The water inlet line is connected to the water
valve. This valve is located just behind the front
panel of the ice machine.

DRAIN CONNECTIONS

Follow these guidelines when installing drain lines to
prevent drain water from flowing back into the ice
machine and storage bin:
Drain lines must have a 2.5 cm drop per 1 meter of
run (1.5 inch per 5 feet), and must not create traps.
The floor drain must be large enough to
accommodate drainage from all drains.
Insulate the bin drain line to prevent condensation.
Section 2
Part Number 040001360 6/14