Section 4
When Used - REMOVE
THUMBSCREWS AND
WATER PUMP COVER
DO NOT SOAK
WATER PUMP MOTOR IN
CLEANER OR SANITIZER
SOLUTIONS
Water Pump Removal
D. Remove the Ice Thickness Probe
• Compress the side of the ice thickness probe
near the top hinge pin and remove it from the
bracket.
NOTE: At this point, the ice thickness probe can easily
be cleaned. If complete removal is desired follow the ice
thickness probe wire to the bulkhead grommet (exit
point) in the back wall. Pop the bulkhead grommet out of
the back wall by inserting fingernails or a flat object
between the back wall and the grommet and prying
forward. Pull the bulkhead grommet and wire forward
until the connector is accessible, then disconnect the
wire lead from the connector.
Part Number 040001360 6/14
.
Ice Thickness Probe Cleaning
Mix a solution of Manitowoc ice machine cleaner and
water (2 ounces of cleaner to 16 ounces of water) in
a container.
Soak the ice thickness probe a minimum of 10
minutes.
Clean all ice thickness probe surfaces and verify the ice
thickness probe cavity is clean. Rinse thoroughly with
clean water, then dry completely. Incomplete rinsing and
drying of the ice thickness probe can cause premature
harvest.
E. Remove the Water Distribution Tube
1. LIFT UP
2. SLIDE BACK
3. SLIDE TO RIGHT
DISTRIBUTION
TUBE
THUMBSCREW
Loosen the two thumbscrews, which secure the
distribution tube.
Lift the right side of the distribution tube up off the
locating pin, then slide it back and to the right.
! Caution
Do not force this removal. Be sure the locating pin is
clear of the hole before sliding the distribution tube
out.
Maintenance
2
3
1
THUMBSCREW
LOCATING
PIN
13