Types 2030, 2031, 2031 K, 2032,
Structure and Function
Media
Control medium
neutral gases, air
Flow media
Type 2030; contaminated and aggressive
media
Types 2031, 2031 K, 2032, 2033
and 2037; contaminated, aggressive,
ultra-pure, sterile media and media with
higher viscosity.
installation position
any position, preferably with the actuator
face up.
Tank bottom valve Type 2033: Actuator to
the bottom
2033, 2037
7.
sTrucTure and funcTiOn
7.1.
structure
7.1.1.
2/2-way valve type 2030, 2031 and
2031 K
The piston-controlled diaphragm valve consists of a pneumatically
actuated piston actuator and a 2/2-way valve housing.
Fig. 20:
Structure and description
English
Transparent cap with position
indicator
Actuator housing
Upper control air connection
(for CFB and CFI)
Lower control air connection
(for CFA and CFI)
Diaphragm socket
Diaphragm housing
Port connection
21