Burkert 2030 Manuel D'utilisation page 33

Vannes à membrane, commandé par piston
Masquer les pouces Voir aussi pour 2030:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Types 2030, 2031, 2031 K, 2032,
example
Housing
4 fastening
screws
Mark tab for direction
Fig. 30:
Replacement of diaphragm
2033, 2037
Repairs
Upper control air con-
nection
(for CFB and CFI)
Lower control air con-
nection
(for CFA and CFI)
Diaphragm
of flow
replacement of the diaphragm for control function a
Clamp the valve housing in a holding device (applies only to valves
not yet installed).
Pressurize lower control air connection with compressed air (value
as indicated on the rating plate) (see picture below Fig. 31:Control
air connection). This is required to detach the diaphragm without
damage from the housing.
Loosen fastening screws crosswise and remove actuator together
with diaphragm from the housing.
Unbutton or unscrew the old diaphragm. If attachment is with a
bayonet catch, remove the diaphragm by rotating it through 90°
(see Tab. 10:Fastening types for diaphragms).
Install new diaphragm in actuator (see
for diaphragms).
Align diaphragm.
Observe mark tab for direction of flow!
Place actuator back on the housing.
Lightly cross-tighten the housing screws until the diaphragm is
between the housing and actuator.
do not tighten the screws yet.
Actuate the diaphragm valve twice to position the diaphragm
correctly.
Without applying pressure, tighten the housing screws to the
permitted tightening torque (see Tab. 11:Tightening torques for
diaphragms).
Pressurize lower control air connection with compressed air (value
as indicated on the rating plate).
English
Tab. 10:Fastening types