2.3 Product life cycle handling
2.3.1 Transport
Transport the SERVOSTAR 300 in accordance with IEC 61800-2 as follows:
Only by qualified personnel in the manufacturer's original recyclable packaging
Avoid shocks
Temperature: –25 to +70°C, max. 20K/hr rate of change,
class 2K3 acc. to EN61800-2, EN 60721-3-1
Humidity: max. 95% relative humidity, no condensation,
class 2K3 acc. to EN61800-2, EN 60721-3-1
If the packaging is damaged, check the unit for visible damage. In this case, inform the
shipper and the manufacturer.
The servo amplifiers contain electrostatically sensitive components which can be damaged
by incorrect handling. Discharge yourself before touching the servo amplifier. Avoid contact
with highly insulating materials (artificial fabrics, plastic films etc.). Place the servo amplifier
on a conductive surface.
2.3.2 Packaging
The SERVOSTAR 300 packaging consists of recyclable cardboard with inserts.
Dimensions (HxWxD): 115x365x275mm
Labeling : nameplate outside at the box
2.3.3 Storage
Store the SERVOSTAR 300 in accordance with IEC 61800-2 as follows:
Storage only in the manufacturer's original recyclable packaging
Max. stacking height 8 cartons
Storage temperature: -25 to +55°C, max. rate of change 20°C / hour
class 1K4 acc. to EN61800-2, EN 60721-3-1
Storage humidity: 5 ... 95% relative humidity, no condensation
class 1K3 acc. to EN61800-2, EN 60721-3-1
Storage duration: Less than 1 year without restriction.
More than 1 year: capacitors must be re-formed before setting up and operating the servo
amplifier. To do this, remove all electrical connections and apply single-phase 230V AC
for about 30 minutes to the terminals L1 / L2.
2.3.4 Installation, setup and normal operation
Installation and setup information are given in this manual:
Mechanical installation (➜ # 52)
Electrical installation (➜ # 53)
Setup (➜ # 55)
Normal operation tested for environmental class 3K3 according to IEC 61800-2 (➜ # 46).
The manufacturer of the machine defines the necessary end user expertise based on the risk
assessment for the machine and describes the requirements for normal operation based on
the application.
S300 Product Safety Guide | 2 English