Cisco Aironet 1300 Serie Instructions De Montage page 8

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Safety Precautions
Typical Access Point Installation Components
The access point is designed to be installed in an indoor or outdoor environment, typically on a wall,
tower, or tall building. A typical installation diagram is shown in
Figure 1
Ground wires must comply with Sections 810 and 820 of the National Electrical Code and Section 54 of
Note
the Canadian Electrical Code.
This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the
Warning
absence of a suitably installed ground conductor. Contact the appropriate electrical inspection
authority or an electrician if you are uncertain that suitable grounding is available. Statement 1024
To ensure correct installation and grounding, install the access point in compliance with your local and
Caution
national electrical codes: National Fire Protection Association (NFPA) 70, National Electrical Code
(U.S.); Canadian Electrical Code, Part I, CSA 22.1 (Canada); and if local or national electrical codes are
not available, refer to IEC 364, Part 1 through 7 (other countries).
Note
The ground block and grounding wire are not required when both the access point and the antenna are
mounted in a sheltered indoor environment.