Mounting the Access Point
Cut the cables to length, install F-connectors on the ends, and connect them to the grounding block.
Step 4
Caution
Note
Find the building's grounding electrode system and then connect the access point ground lug to it using
Step 5
6 AWG copper wire. Use a crimping tool to crimp the wire to the ground lug. For more information about
attaching the ground lug to the access point, see
to the Access Point" section on page
Caution
Note
For outdoor locations, weather seal all coaxial connectors by wrapping them with the sealant tape
Step 6
provided with the installation kit. For more information, see the
page

Tower Mount

A professional installer must install the access point on a tower. A professional installer has skills and
knowledge related to the construction, operation, and installation of electrical equipment and has
received safety training on the hazards involved.
Installing the access point on a tower includes the following subtasks:
Mounting the access point
1.
2.
Routing the cables (normal or lightning protected)
Activating the link
3.
This warning applies to outdoor access point installations.
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Warning
Statement 1030
Cisco Aironet 1300 Series Lightweight Outdoor Access Point Mounting Instructions
20
To prevent damage to the access point or power injector, connect all coax cables from the
power injector to the access point and connect the power jack to the power injector before
applying power.
The grounding block must be connected to the building's grounding electrode system by
14 AWG copper wire or larger.
To ensure correct installation and grounding, install the access point in compliance with your
local and national electrical codes: National Fire Protection Association (NFPA) 70, National
Electrical Code (U.S.); Canadian Electrical Code, Part I, CSA 22.1 (Canada); and if local or
national electrical codes are not available, refer to IEC 364, Part I through Part 7 (other
countries).
Local code may require grounding of the rooftop mount.
26.
Step 3
and
Step 4
30. See
Figure 11
for the ground lug location.
"Applying Coax Seal Tape" section on
in the
"Attaching the Housing Bracket
78-17634-01B0